add charging watchdog

This commit is contained in:
Frank Zechert
2026-08-18 12:25:15 +02:00
parent 2e546e1ebb
commit aed8cf9dd3
5 changed files with 280 additions and 7 deletions
+3 -1
View File
@@ -76,7 +76,9 @@
.config/spicetify .config/spicetify
.config/spotify .config/spotify
.config/spotify-launcher.conf .config/spotify-launcher.conf
.config/systemd # Ignore only the symlink farms generated by `systemctl --user enable`,
# so that real unit files can still be managed.
.config/systemd/user/*.wants
.config/teams-for-linux .config/teams-for-linux
.config/yay .config/yay
@@ -0,0 +1,33 @@
{{- if eq .chezmoi.os "linux" -}}
#!/usr/bin/env bash
#
# Enable the battery charge-controller watchdog.
#
# Re-runs whenever the unit or the watchdog script changes, so that an
# already-running instance picks up the new version.
set -e
[ "${CHEZMOI}" -eq 1 ] || exit 1
# unit hash: {{ include (joinPath .chezmoi.sourceDir "dot_config/systemd/user/battery-charge-watchdog.service") | sha256sum }}
# script hash: {{ include (joinPath .chezmoi.sourceDir "dot_config/scripts/executable_battery-charge-watchdog.sh") | sha256sum }}
# Applying from a TTY or a container has no user bus; skip rather than
# aborting the whole apply.
if ! systemctl --user show-environment > /dev/null 2>&1; then
echo "No systemd user session, skipping battery-charge-watchdog activation"
exit 0
fi
systemctl --user daemon-reload
# The unit carries ConditionPathExists on the battery, so enabling it on a
# machine without one is harmless: it simply never starts.
systemctl --user enable --now battery-charge-watchdog.service
# enable --now will not restart an instance that is already running, so an
# updated script or unit would otherwise not take effect until next login.
systemctl --user try-restart battery-charge-watchdog.service
# vim: syntax=bash ft=template
{{- end -}}
@@ -364,24 +364,24 @@
"acLockTimeout": 1800, "acLockTimeout": 1800,
"acSuspendTimeout": 0, "acSuspendTimeout": 0,
"acSuspendBehavior": 0, "acSuspendBehavior": 0,
"acProfileName": "", "acProfileName": "2",
"acPostLockMonitorTimeout": 3600, "acPostLockMonitorTimeout": 3600,
"batteryMonitorTimeout": 600, "batteryMonitorTimeout": 600,
"batteryLockTimeout": 300, "batteryLockTimeout": 300,
"batterySuspendTimeout": 3600, "batterySuspendTimeout": 3600,
"batterySuspendBehavior": 2, "batterySuspendBehavior": 2,
"batteryProfileName": "", "batteryProfileName": "0",
"batteryPostLockMonitorTimeout": 300, "batteryPostLockMonitorTimeout": 300,
"batteryChargeLimit": 100, "batteryChargeLimit": 100,
"batteryNotifyChargeLimit": false, "batteryNotifyChargeLimit": true,
"batteryCriticalThreshold": 5, "batteryCriticalThreshold": 10,
"batteryNotifyCritical": true, "batteryNotifyCritical": true,
"batteryLowThreshold": 15, "batteryLowThreshold": 15,
"batteryNotifyLow": true, "batteryNotifyLow": true,
"batteryChargeLimitNotificationType": 0, "batteryChargeLimitNotificationType": 1,
"batteryLowNotificationType": 1, "batteryLowNotificationType": 1,
"batteryCriticalNotificationType": 1, "batteryCriticalNotificationType": 1,
"batteryAutoPowerSaver": false, "batteryAutoPowerSaver": true,
"lockBeforeSuspend": true, "lockBeforeSuspend": true,
"loginctlLockIntegration": true, "loginctlLockIntegration": true,
"fadeToLockEnabled": true, "fadeToLockEnabled": true,
@@ -0,0 +1,206 @@
#!/usr/bin/env bash
#
# battery-charge-watchdog
#
# Detects the Dell/UCSI fault where the battery reports a non-discharging
# status (Charging / Full / Not charging) while charge_now is actually
# falling. In that state UPower never fires CriticalPowerAction, so the
# machine runs to 0% and dies with no warning and no clean shutdown.
#
# The only trustworthy signal is the charge_now trend: current_now is
# reported unsigned on this hardware, so its sign says nothing about
# direction, and `status` is precisely what lies during the fault.
#
# Raises a critical desktop notification and keeps re-raising it until
# charging genuinely resumes or the status turns honest (Discharging,
# where UPower's own safety net takes over again).
set -uo pipefail
BAT=${BAT:-/sys/class/power_supply/BAT0}
AC=${AC:-/sys/class/power_supply/AC}
# How often to sample.
POLL_INTERVAL=${POLL_INTERVAL:-20}
# How often to re-raise the alert while the fault persists.
REPEAT_INTERVAL=${REPEAT_INTERVAL:-60}
# Drop below the running peak, in 1/1000ths of full charge, before we
# call it a fault. 15 = 1.5% of full charge, comfortably above gauge jitter.
DROP_PERMILLE=${DROP_PERMILLE:-15}
# Emergency hibernate floor, in percent. 0 disables it (default: notify only).
HIBERNATE_AT=${HIBERNATE_AT:-0}
# Statuses that mean "UPower will not treat this as discharging", and so
# will not act on PercentageAction no matter how low the battery gets.
is_lying_status() {
case "$1" in
Charging | Full | "Not charging" | Unknown) return 0 ;;
*) return 1 ;;
esac
}
# sysfs reads can block for minutes when the UCSI/PD controller wedges,
# which is the very condition we are watching for. Never read unguarded.
read_attr() {
local v
v=$(timeout 5 cat "$1" 2>/dev/null) || return 1
[[ -n $v ]] || return 1
printf '%s' "$v"
}
read_int() {
local v
v=$(read_attr "$1") || return 1
[[ $v =~ ^-?[0-9]+$ ]] || return 1
printf '%s' "$v"
}
log() { printf '%s %s\n' "$(date '+%F %T')" "$*"; }
notify_id=0
notify() {
local urgency=$1 timeout_ms=$2 title=$3 body=$4 fresh=${5:-0}
local args=(-a "Battery Watchdog" -u "$urgency" -t "$timeout_ms"
-h string:category:device -i battery-caution)
# Reuse one notification so the alert updates in place instead of
# stacking, except when we deliberately want a new one to pop.
if [[ $fresh -eq 0 && $notify_id -gt 0 ]]; then
notify-send "${args[@]}" -r "$notify_id" "$title" "$body" >/dev/null 2>&1
else
local id
id=$(notify-send "${args[@]}" -p "$title" "$body" 2>/dev/null) && notify_id=$id
fi
}
fmt_duration() {
local s=$1
((s < 0)) && s=0
if ((s < 3600)); then
printf '%dm' $(((s + 30) / 60))
else
printf '%dh%02dm' $((s / 3600)) $(((s % 3600) / 60))
fi
}
charge_full=$(read_int "$BAT/charge_full") || {
log "FATAL: cannot read $BAT/charge_full"
exit 1
}
((charge_full > 0)) || {
log "FATAL: charge_full is $charge_full"
exit 1
}
drop_threshold=$((charge_full * DROP_PERMILLE / 1000))
# Clearing the alert needs less movement than raising it: real charging
# adds roughly 1%/min here, so this confirms recovery within a minute.
recover_threshold=$((drop_threshold / 3))
((recover_threshold > 0)) || recover_threshold=1
log "started: charge_full=${charge_full}uAh threshold=${drop_threshold}uAh" \
"poll=${POLL_INTERVAL}s repeat=${REPEAT_INTERVAL}s hibernate_at=${HIBERNATE_AT}%"
peak=0 # highest charge_now seen in the current non-discharging run
trough=0 # low-water mark within the current fault, for recovery
alerting=0 # are we currently in the fault state
alert_start_t=0 # when the fault was first detected
alert_start_c=0 # charge_now at that moment
last_notify=0
last_escalation=100
while :; do
now=$(date +%s)
status=$(read_attr "$BAT/status") || status="Unreadable"
charge=$(read_int "$BAT/charge_now") || charge=""
capacity=$(read_int "$BAT/capacity") || capacity=""
ac=$(read_int "$AC/online") || ac="?"
if [[ -z $charge ]]; then
# A hung or unreadable gauge is itself a symptom worth surfacing.
log "WARN: charge_now unreadable (status=$status)"
sleep "$POLL_INTERVAL"
continue
fi
if is_lying_status "$status"; then
if ((alerting)); then
# Recovery is measured against the low-water mark of this fault,
# not the pre-fault peak: after draining 90%->50%, real charging
# must clear the alert promptly, not on the way back up to 90%.
((charge < trough)) && trough=$charge
if ((charge - trough >= recover_threshold)); then
log "RESOLVED: charging resumed (status=$status capacity=${capacity}%)"
notify normal 10000 "Battery charging restored" \
"Charge is rising again at ${capacity}%. Status: ${status}." 1
alerting=0
peak=$charge
last_escalation=100
fi
else
((charge > peak)) && peak=$charge
deficit=$((peak - charge))
if ((deficit >= drop_threshold)); then
alerting=1
trough=$charge
alert_start_t=$now
alert_start_c=$charge
last_notify=0
log "FAULT: status=$status but charge fell ${deficit}uAh from peak" \
"(capacity=${capacity}% ac_online=${ac})"
fi
fi
if ((alerting)); then
deficit=$((peak - charge))
if ((now - last_notify >= REPEAT_INTERVAL)); then
elapsed=$((now - alert_start_t))
drained=$((alert_start_c - charge))
eta=""
# Need a wide enough window for the rate to mean anything;
# over a few seconds the gauge quantisation dominates.
if ((elapsed >= 60 && drained > 0)); then
# seconds until charge_now hits zero at the observed rate
eta=$(fmt_duration $((charge * elapsed / drained)))
eta=" Est. ${eta} to empty."
fi
# Pop a brand-new notification when crossing a danger step,
# so it is not silently folded into the existing one.
fresh=0
for step in 20 10 5; do
if [[ -n $capacity ]] && ((capacity <= step && last_escalation > step)); then
last_escalation=$step
fresh=1
break
fi
done
notify critical 0 "⚠ Battery draining while reporting \"${status}\"" \
"Charge controller fault: ${capacity}% and falling, but status reads \"${status}\" and AC online=${ac}.${eta}
UPower will NOT hibernate in this state. Reseat the USB-C/dock cable or save your work now." \
"$fresh"
log "ALERT: capacity=${capacity}% status=$status deficit=${deficit}uAh${eta}"
last_notify=$now
fi
if ((HIBERNATE_AT > 0)) && [[ -n $capacity ]] && ((capacity <= HIBERNATE_AT)); then
log "EMERGENCY: capacity=${capacity}% <= ${HIBERNATE_AT}%, hibernating"
notify critical 0 "Hibernating now" \
"Battery at ${capacity}% with a charge-controller fault." 1
systemctl hibernate
fi
fi
else
# Discharging or similar: honest reporting, UPower handles it.
if ((alerting)); then
log "RESOLVED: status turned honest ($status) - UPower safety net active again"
notify normal 10000 "Battery status corrected" \
"Now reporting \"${status}\" at ${capacity}%. Normal low-battery handling applies." 1
alerting=0
last_escalation=100
fi
peak=0
fi
sleep "$POLL_INTERVAL"
done
@@ -0,0 +1,32 @@
[Unit]
Description=Battery charge-controller fault watchdog
Documentation=man:notify-send(1)
# Needs the session bus for notifications.
After=graphical-session.target
PartOf=graphical-session.target
# Makes the unit inert on machines without a battery, so it can be
# enabled unconditionally on the desktop as well as the laptop.
ConditionPathExists=/sys/class/power_supply/BAT0/charge_now
[Service]
Type=simple
ExecStart=%h/.config/scripts/battery-charge-watchdog.sh
Restart=always
RestartSec=10
# Set HIBERNATE_AT=5 to add an emergency hibernate floor (0 = notify only).
Environment=POLL_INTERVAL=20
Environment=REPEAT_INTERVAL=60
Environment=DROP_PERMILLE=15
Environment=HIBERNATE_AT=0
# Read-only monitoring; no need for any write access to the system.
ProtectSystem=strict
ProtectHome=read-only
PrivateTmp=yes
NoNewPrivileges=yes
RestrictNamespaces=yes
MemoryMax=64M
[Install]
WantedBy=graphical-session.target